HP proliant SERVER hardware command

to check the failed disk, adapter, any physical component on hp prolient server use the below important command.

# hpacucli controller all show config———-to See the failed disk in HP proliadownloadnt server

Smart Array P410i in Slot 0 (Embedded) (sn: 500143802590F6C0)

logicaldrive 1 (558.9 GB, RAID 1, Interim Recovery Mode)
array A (SAS, Unused Space: 0 MB)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, Failed)====>indicating the faild drive

SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143802590F6CF)

[root@TEST:/root]# hpacucli ctrl slot=0 show

Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 500143802590F6C0
Cache Serial Number: PBCDH0CRH1Z6R3
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 6.60
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 400 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True

By: Bibhuti Bhusan

Leave a comment